ac

Samsung AC Error Codes: Complete List and Troubleshooting

Samsung AC Error Codes: Complete List and Troubleshooting

Find the complete list of Samsung Air Conditioner error codes and troubleshooting tips for common AC issues. Learn how to fix cooling problems and get expert Samsung AC repair services in Bhubaneswar and Odisha.

Samsung air conditioners are known for their performance and durability, but like any electronic appliance, they may occasionally show error codes to indicate malfunctions. These error codes are essential for identifying and addressing issues quickly, saving time and effort in fixing the problems. Below is a list of Samsung AC error codes, along with their possible causes and solutions.


**1. E1 – Indoor Unit Sensor Error

Cause: This error indicates a malfunction with the indoor unit’s temperature sensor, which is crucial for regulating the air conditioner’s cooling or heating functions.

Solution: Inspect the sensor for dirt or damage. If cleaning doesn’t fix the issue, it may need to be replaced by a technician.


**2. E2 – Outdoor Unit Sensor Error

Cause: The E2 error code points to a malfunction in the outdoor unit’s temperature sensor. This could affect the system’s ability to cool or heat the space effectively.

Solution: Check for any visible damage to the sensor. If the issue persists, the sensor may need to be replaced by a technician.


**3. E3 – Communication Error Between Indoor and Outdoor Units

Cause: The E3 code signifies a failure in communication between the indoor and outdoor units, usually due to wiring issues or faulty connections.

Solution: Check the wiring between the indoor and outdoor units. If the connections appear intact, the control board may need to be replaced or repaired by a professional.


**4. E4 – High Pressure Protection

Cause: This error is triggered when the system detects high refrigerant pressure, which could be caused by a blocked filter, poor airflow, or an overcharge of refrigerant.

Solution: Clean the air filters and ensure there are no blockages in the system. If the error persists, consult a technician to check the refrigerant levels and adjust them if necessary.


**5. E5 – Low Pressure Protection

Cause: The E5 error code indicates that the refrigerant pressure is too low, typically due to a refrigerant leak or insufficient refrigerant levels.

Solution: If you suspect low refrigerant, call a professional technician to check for leaks and recharge the refrigerant.


**6. E6 – Outdoor Unit Communication Error

Cause: This error occurs when the outdoor unit is unable to communicate with the main control system, usually due to a fault in the outdoor unit’s circuit board or communication wiring.

Solution: Inspect the wiring between the outdoor unit and the control system. If the wiring appears intact, a technician will need to inspect the circuit board for issues.


**7. E7 – Overcurrent Protection

Cause: E7 occurs when an overcurrent is detected in the system, possibly caused by a short circuit or malfunctioning electrical components.

Solution: Check the circuit breaker and ensure the AC is receiving stable power. If the error continues, consult an electrician or technician to inspect the unit’s internal electrical components.


**8. F0 – Indoor Unit Malfunction

Cause: The F0 error code indicates a general malfunction in the indoor unit, often related to issues with the fan motor or the control board.

Solution: Turn off the unit and inspect the fan and control board for visible damage. If you cannot find a solution, call a technician to check for internal issues.


**9. F1 – Indoor Unit Circuit Board Error

Cause: This error points to a malfunction with the indoor unit’s circuit board, which controls the AC’s operation.

Solution: A faulty circuit board may need to be replaced. You can check the circuit board for visible damage, but it is often best to have a technician handle this repair.


**10. F3 – Outdoor Temperature Sensor Error

Cause: The F3 error code signals a malfunction with the outdoor unit’s temperature sensor, which is essential for the AC’s cooling and heating functions.

Solution: Inspect the outdoor temperature sensor for damage or dirt. If cleaning doesn’t resolve the issue, you may need to replace the sensor.


**11. F4 – Faulty Humidity Sensor

Cause: The F4 code indicates a malfunction with the humidity sensor, which regulates moisture levels in the air. This can affect the system’s cooling and dehumidifying abilities.

Solution: Clean the humidity sensor or replace it if damaged.


**12. U0 – General Unit Error

Cause: This error occurs when there is an unspecified issue with the air conditioning unit. It can result from a variety of internal problems, including sensor malfunctions or electrical failures.

Solution: Try resetting the unit by turning it off and unplugging it for a few minutes. If the error continues, contact a technician to diagnose and repair the problem.


**13. U1 – High Voltage Protection

Cause: The U1 error code is triggered when the AC detects a high voltage, which could damage sensitive components like the compressor and control board.

Solution: Check your home’s power supply and ensure it is stable. If high voltage continues to be an issue, consider installing a surge protector or voltage stabilizer to protect your AC from electrical fluctuations.


**14. U2 – Low Voltage Protection

Cause: This error indicates that the AC is receiving low voltage, which can prevent the unit from working efficiently.

Solution: Ensure that the AC is receiving a stable and sufficient power supply. If voltage issues persist, using a voltage stabilizer may be necessary.


**15. U3 – Internal Communication Error

Cause: U3 signifies a communication error within the internal components of the air conditioner, often related to the control board or other electrical systems.

Solution: A technician will need to inspect the system’s internal wiring and components to identify and resolve the communication error.


Explore the complete list of Samsung Air Conditioner error codes and troubleshooting solutions for common AC issues. Get expert advice on fixing cooling problems and find reliable Samsung AC repair services in Bhubaneswar and Odisha.

Tags: Samsung AC, error codes, Samsung air conditioner issues, AC error codes, Samsung AC troubleshooting, AC diagnostic, Samsung AC not cooling, Samsung AC repair, HVAC error codes, Samsung cooling problems, Samsung AC fault codes, air conditioner not working, Samsung AC maintenance, Bhubaneswar AC repair, Odisha Samsung AC service, Bhubaneswar air conditioner repair, Samsung AC fault, AC troubleshooting steps, Samsung AC problems, AC refrigerant leak, Samsung air conditioner diagnostic, Odisha AC repair, Bhubaneswar HVAC services, Samsung AC problems fix, Samsung AC service Bhubaneswar

 

Code Possible Cause
Ch Prohibit starting during operation of the Crack case heater
E108 Error due to repeated communication address
E121 Error on room temperature sensor of indoor unit (Short or Open)
E122 Error on EVA IN sensor of indoor unit (Short or Open)
E123 Error on EVA OUT sensor of indoor unit (Short or Open)
E124 Communication error sends from indoor unit
E128 Indoor unit EVA IN sensor breakaway
E129 Indoor unit EVA OUT sensor breakaway
E131 Indoor unit heater sensor error
E151 Indoor unit EEV open failure(When 2* detection)
E152 Indoor unit EEV close failure(When 2“ detection)
E153 Indoor unit floating S/V error(When 2“ detection)
E154 Indoor unit fan error
E162 Outdoor unit EEPROM error
E198 Error on thermal fuse of indoor unit (Open)
E201 Communication error between indoor unit and outdoor unit (Pre tracking failure or when actual number of indoor units are different from the indoor unit quantity setting on the outdoor unit) Error due to communication tracking failure after initial power supply (The error occurs with the failure regardless of the number of devices)
E202 Communication error between indoor and outdoor unit (When not received in every room after completing the tracking)
E203 Communication error between outdoor unit inv – main micom (For PF #4~#6 controller, error will be determined from the time when compressor turns on)
E221 Error on outdoor temperature sensor (Short or Open)
E231 Error on outdoor COND OUT sensor (Short or Open)
E241 COND OUT sensor breakaway
E251 Digital comp.1 discharge temperature sensor(Short or Open)
E256 Fixed comp.1 discharge temperature sensor(Short or Open)
E257 Fixed comp.2 discharge temperature sensor(Short or Open)
E258 Fixed comp.3 discharge temperature sensor(Short or Open)
E262 Fixed compl Discharge temperature sensor breakaway
E263 Fixed comp2 Discharge temperature sensor breakaway
E264 Fixed comp3 Discharge temperature sensor breakaway
E265 Digital compl Sump temperature sensor breakaway. Fixed compl Sump temperature sensor breakaway
E267 Fixed comp2 Sump temperature sensor breakaway
E268 Fixed comp3 Sump temperature sensor breakaway
E269 Suction temperature sensor breakaway
E271 Comp.1 Sump temperature sensor(Short or Open)
E291 High pressure sensor(Short or Open)
E296 Low pressure sensor(Short or Open)
E307 Oil balance sensorl (Short or Open)
E308 Suction sensor(Short or Open)
E311 Double pipe sensor(Short or Open)
E320 Error on OLP sensor (Short or Open)
E403 Compressor down due to freeze protection control
E404 System stop due to overload protection control
E407 Comp, down by high pressure
E410 Comp, down by low pressure
E413 Comp, down by the sump protection control
E416 Comp, down by the discharge temperature sensor
E422 Blockage detected on high pressure pipe
E425 Reverse phase or open phase
E428 Comp down by compression ratio control
E431 Equal oil valve 1 self diagnosis
E440 Heating operation restricted at outdoor temperature overheating value (default: 30 °C)
E441 Cooling operation restricted at outdoor temperature below cool value (default 0°Q
E442 Forbid an operation during heat mode with refrigerant charging operation when outdoor temperature is over 15°C
E443 Start prohibition by refrigerant pressure error
E452 Instant power off error
E453 Fan motor hifi temperature error
E454 Fan motor RPM error
E455 Fan motor IPM high temperature error
E456 Fan motor over current error
E457 Fan motor reverse rotation error
E458 Fan speed error
E461 Error due to operation failure of inverter compressor
E461 CTJow current
E462 System stop due to full current control
E463 System stop due to OLP temperature control
E464 System stop due to DC Peak
E465 Compressor overload prevention
E466 DC-Link voltage under/over error
E467 Error due to abnormal rotation of the compressor or unconnected wire of compressor
E468 Error on current sensor (Short or Open)
E469 Error on DC-Link voltage sensor (Short or Open)
E470 Outdoor unit EEPROM Read/Write error (Option)
E471 Outdoor unit EEPROM Read/Write error (H/W)
E472 AC Line Zero Cross Signal out
E473 Comp Lock error
E474 Error on IPM Heat Sink sensor of inverter 1 (Short or Open)
E475 Error of inverter fan 2
E484 PFC Overload (Over current) Error
E485 Error on input current sensor of inverter 1 (Short or Open)
E500 IPM over heat error on inverter 1
E508 Smart install is not installed
E554 Gas leak detected
E556 Error due to mismatching capacity of indoor and outdoor unit
E557 DPM remote controller option error
E560 Switch option setting error(rvot applied)
E590 Inverter EEPROM Checksum error
E660 Error of inverter Boot Code
P701 Indoor unit floating S/V error(When 1“ detection)
P702 Indoor unit EEV close failure(When 1“ detection)
P703 Indoor unit EEV open failure(When 1“ detection)

 

Final Thoughts:

Samsung AC error codes are designed to help you troubleshoot common issues quickly. While many problems can be addressed through basic maintenance or simple fixes, some require professional attention. For issues related to refrigerant, sensors, or circuit boards, it’s always best to contact a certified technician to prevent further damage and ensure your air conditioner operates at peak performance. Regular servicing and attention to error codes can help maintain your Samsung AC’s longevity and efficiency.

Comments are closed.