Service Center ac 1

Panasonic AC Error Codes: The Complete List and Troubleshooting Guide

Panasonic air conditioners are well-regarded for their reliability and performance, but like all appliances, they may encounter issues that trigger error codes. These error codes help users quickly identify and troubleshoot problems with their AC units, potentially saving time and money on repairs. Below is a complete list of common Panasonic air conditioner error codes, their meanings, and possible solutions.

Panasonic Air Conditioner Error Codes: The Complete List and What They Mean


1. E1 – Indoor Unit Sensor Error

This error code indicates a problem with the indoor temperature sensor, which may be malfunctioning or disconnected. The sensor monitors the room temperature and adjusts cooling accordingly.

Solution: Check the sensor for dirt or damage. If cleaning it doesn’t resolve the issue, the sensor may need to be replaced.


2. E2 – Outdoor Unit Sensor Error

Similar to the E1 error, this code refers to a problem with the temperature sensor in the outdoor unit. This sensor helps the unit regulate cooling by detecting outdoor air temperature.

Solution: Inspect the outdoor temperature sensor for any visible damage. If there’s no apparent issue, the sensor might need professional replacement.


3. E3 – Communication Error Between Indoor and Outdoor Units

This error occurs when the indoor and outdoor units fail to communicate with each other. It could be caused by wiring issues, a power surge, or a malfunctioning control board.

Solution: Check the connections between the indoor and outdoor units. If the wiring seems intact, the control board might need to be inspected or replaced by a technician.


4. E4 – High Pressure Protection

The E4 error code indicates that the refrigerant pressure inside the system is too high, which could be due to a blocked or dirty filter, or a refrigerant overcharge.

Solution: Clean or replace the air filters to ensure proper airflow. If the issue persists, the refrigerant charge may need to be adjusted or the system may need to be inspected for blockages.


5. E5 – Low Pressure Protection

This code signifies that the refrigerant pressure is too low, often due to a refrigerant leak or insufficient refrigerant levels.

Solution: If this error appears, it’s essential to contact a professional to check for leaks and recharge the refrigerant. Low refrigerant can seriously damage the compressor if left unchecked.


6. E6 – Outdoor Unit Communication Error

An issue with communication between the outdoor unit and the main control system triggers the E6 error. It could be caused by faulty wiring or an issue with the outdoor unit’s circuit board.

Solution: Ensure that the communication cables between the outdoor unit and the main system are intact. If the issue persists, a professional inspection may be needed.


7. E7 – Overcurrent Protection

The E7 error code appears when the air conditioner detects an electrical overcurrent, which can occur due to problems like a short circuit or faulty electrical components.

Solution: Turn off the unit and check the circuit breaker. If the issue is not resolved, contact a technician to inspect the internal wiring and components for damage or malfunction.


8. E8 – Outdoor Unit Overheating

This code indicates that the outdoor unit is overheating, likely due to a blocked condenser coil, poor airflow, or insufficient refrigerant levels.

Solution: Clean the outdoor condenser coil to remove dust and debris. Make sure there are no obstructions around the unit. If the problem persists, have the refrigerant levels checked.


9. F0 – Indoor Unit Malfunction

The F0 error code indicates a malfunction in the indoor unit, often related to the fan motor or control board.

Solution: Check the fan and other components in the indoor unit for any visible issues. If the fan isn’t working, it may need to be repaired or replaced.


10. F1 – Indoor Unit Circuit Board Malfunction

This code signals a problem with the indoor unit’s control circuit board, which could be caused by power surges or component failure.

Solution: Power off the unit and check the circuit board for any visible damage. In most cases, the control board will need to be replaced by a professional technician.


11. F3 – Faulty External Temperature Sensor

The F3 code indicates a malfunction with the external temperature sensor, which could be causing inaccurate readings for cooling.

Solution: Inspect the sensor for any signs of damage or dirt. If cleaning doesn’t help, the sensor may need to be replaced.


12. F4 – Faulty Humidity Sensor

This code appears when the humidity sensor is not working properly, which can affect the air conditioner’s ability to regulate moisture levels.

Solution: Clean or replace the humidity sensor if it appears damaged. If you are unsure, a professional technician can handle the repair.


13. U0 – AC Unit Error

A U0 error signifies a general malfunction of the air conditioner. This can be triggered by various internal issues, ranging from sensor problems to electrical faults.

Solution: Reset the AC unit by turning it off and unplugging it for a few minutes. If the issue persists, consult a professional to diagnose the problem.


14. U1 – High Voltage Protection

This error indicates that the AC has detected high voltage in the system, which could damage internal components like the compressor or control board.

Solution: Check your home’s power supply to ensure that it is stable and not experiencing power surges. If the issue is persistent, a voltage stabilizer or surge protector may be necessary.


Discover the complete list of Panasonic Air Conditioner error codes and their meanings. Learn how to troubleshoot common AC issues, including cooling problems, and find expert repair services in Bhubaneswar and Odisha.

Tags: Panasonic Air Conditioner, error codes, Panasonic AC, AC error codes, Panasonic air conditioner issues, Panasonic AC troubleshooting, AC diagnostic codes, Panasonic AC repair, HVAC error codes, Panasonic AC problems, error code list, air conditioner not working, Panasonic AC maintenance, AC fault codes, Panasonic cooling issues, Bhubaneswar AC repair, Odisha Panasonic AC service, Bhubaneswar air conditioner service, AC error code meanings, Panasonic AC fault troubleshooting, Bhubaneswar Panasonic repair, Odisha AC repair, Panasonic AC not cooling, air conditioner repair Bhubaneswar

Code Possible Cause
00H No detected abnormalities
11H Error of data line between indoor unit and outdoor unit
12H Other power error between outdoor unit and indoor unit
14H Room temperature sensor error
15H Compressor temperature sensor error
16H Compressor load current is too low
19H Internal fan block error
23H Chiller temperature sensor error
25H Error e-ion circuit
27H Outdoor temperature sensor error
28H Hot rig temperature sensor error
30H Compressor output temperature sensor error
33H Error connecting internal and external blocks
38H Internal and external block error is not synchronized
58H PATROL circuit error
59H ECO PATROL circuit error
97H Error on the outdoor unit fan
98H Indoor temperature is too high (heating mode)
99H Chilled temperature is too low (freeze)
11F Cooling mode / Heating switch error
90F Bost booster circuit fault for compressor compressor power block
91F Compressor load line error is too low
93F Compressor rotation speed error
95F Hot platform temperature is too high
96F Compressor power transistor overheat (IPM)
97F Compressor temperature is too high
98F Compressor load is too high
99F The DC output to the compressor is too high

 

Final Thoughts:
Understanding these error codes can help you quickly identify and troubleshoot issues with your Panasonic air conditioner. While many of these problems can be solved with basic maintenance or a simple reset, more complex issues—especially those related to refrigerant levels, sensors, or electrical components—may require the expertise of a professional technician. Regular servicing and cleaning of your AC can prevent many of these errors from occurring and keep your unit running smoothly year-round.

One Response